Why do motors still burn out in the era of variable frequency? How to avoid it?

2025-03-20 15:37:26來源:

With the widespread application of frequency conversion technology, motors have made significant progress in energy conservation, speed regulation, and automation control. However, many users have found that even with the use of a frequency converter, the motor may still burn out. What is the reason behind this? How can we effectively avoid it? This article will delve into the common causes of frequency conversion motor burnout and provide practical and feasible preventive measures.

138deaa250e23c9620be08aba368333a.jpg

1、Common causes of burnout of variable frequency motors

①. Low frequency operation leads to insufficient heat dissipation

When the variable frequency motor operates at low frequencies, the speed of its built-in fan will also decrease, resulting in a significant decrease in heat dissipation capacity. If the motor operates at low frequency for a long time, the internal temperature of the motor will gradually increase, ultimately leading to insulation aging or even burning.

②. Damage caused by harmonics and peak voltage

The PWM waves output by the frequency converter contain a large number of high-frequency harmonics, which can generate additional eddy current losses in the motor windings, leading to local overheating. In addition, the peak voltage (dv/dt) generated during the operation of the inverter switching components may break through the insulation and damage the acceleration motor.

③. Overload or improper parameter settings

If the motor runs in an overloaded state for a long time and the current exceeds the rated value, it will cause the winding to overheat. In addition, setting the acceleration/deceleration time of the frequency converter too short can cause instantaneous current surges and increase the burden on the motor.

④. Insulation aging and high-frequency environment

The high-frequency voltage output by the frequency converter will cause greater stress on the insulation material of the motor, especially in old motors or non frequency conversion dedicated motors, where the insulation aging rate will significantly accelerate.

⑤. Mechanical and Electrical Resonance

The frequency converter may cause mechanical resonance at certain frequencies, leading to bearing wear or winding looseness, which in turn can cause faults.

⑥. External environmental factors

If the operating environment of the motor is harsh (such as high temperature, humidity, and high dust), it will also accelerate the insulation aging and mechanical wear of the motor.

2、How to avoid the burning of variable frequency motors?

①. Choose a frequency conversion dedicated motor

The design of the frequency conversion dedicated motor has been optimized for high-frequency environments, with better insulation performance and heat dissipation capability. When selecting, giving priority to this type of motor can effectively reduce the risk of burning.

②. Optimize heat dissipation conditions

When operating at low frequencies, the self cooling ability of the motor decreases. It is recommended to install an independent cooling fan to forcibly dissipate heat. At the same time, ensure that the motor installation environment is well ventilated and avoid high-temperature operation.

③. Install protective devices

·Reactors and filters: Installing reactors or filters at the output of the frequency converter can effectively suppress harmonics and peak voltages, reducing damage to the motor.

·Dv/dt filter or sine wave filter: These devices can smooth the voltage waveform output by the frequency converter and reduce high-frequency damage.

④. Reasonably set the parameters of the frequency converter

·Acceleration/deceleration time: Set reasonable acceleration/deceleration time based on load characteristics to avoid instantaneous current surges.

·Carrier frequency: Adjust the carrier frequency to a reasonable range (such as 2-4kHz) to balance noise and heat generation issues.

·Minimum operating frequency: Control the minimum operating frequency of the motor to be ≥ 10Hz to ensure self cooling effect.

⑤. Regular maintenance and testing

·Insulation resistance testing: Measure the insulation resistance of the motor every quarter to ensure that the resistance value is greater than 1M Ω.

·Bearing and vibration testing: Regularly check the condition of bearings and motor vibration to avoid mechanical resonance or wear.

·Temperature monitoring: Install temperature sensors to monitor the motor's operating temperature in real-time and detect any abnormalities in a timely manner.

⑥. Avoid overloading operation

Ensure that the motor operates within the rated load range and avoid prolonged overload operation. If the load fluctuates greatly, it is recommended to choose a motor with higher power.

⑦. Improve the operating environment

Keep the operating environment of the motor clean, dry, and ventilated to avoid the impact of high temperature, humidity, and dust on the motor.

The reasons for the burnout of variable frequency motors are complex and diverse, but through scientific selection, reasonable parameter settings, comprehensive protection measures, and regular maintenance, the failure rate can be significantly reduced and the service life of the motor can be extended. In the era of frequency conversion, only by fully understanding the operating characteristics of the motor and taking targeted protective measures can the stable and efficient operation of the equipment be ensured.

Hengda Electric has always been dedicated to the research and development, production, and service of variable frequency motors. With advanced technology and equipment, lean manufacturing processes, reliable product quality, and satisfactory after-sales service, the company provides customers with the most suitable motor professional solutions and creates greater social value.

3dfa4e576a4b3418e554c0afd8631d29.jpg

精品熟人妻一区二区三区四区不卡| 人人狠狠综合久久亚洲婷婷| 7777精品伊人久久久大香线蕉| 亚洲精品国产suv一区| 欧美性大战xxxxx久久久| 亚洲欧美日韩在线一区| 精品一区二区三区东京热| 国产偷人妻精品一区二区在线| 成人做受黄大片| 爱情岛论坛亚洲品质自拍hd| 一本大道无码av天堂| 无码少妇a片一区二区三区 | 中国精品少妇hd| 亚洲色婷婷六月亚洲婷婷6月| 99久久人妻精品免费二区| 国产熟人av一二三区| 欧美性受xxxx狂喷水| 后入内射欧美99二区视频| 国产一区二区精品久久| 狠狠色综合7777久夜色撩人ⅰ| 国产a v无码专区亚洲av| 久久精品水蜜桃av综合天堂| 久久人妻av无码中文专区| 国产精品爱久久久久久久电影蜜臀 | 日韩精品乱码av一区二区 | 日韩人妻无码精品久久| 欧美性xxxx极品少妇| 欧美大片aaaaa免费观看| 国产成人av在线影院| 国产成人精品999在线观看| 国产欧美一区二区精品性色| 中国凸偷窥xxxx自由视频妇科 | 亚洲av无码国产精品色午夜| 国产欧美日韩精品a在线观看| 浮妇高潮喷白浆视频| 一二三四在线视频社区3| 国产一区二区精品丝袜| 婷婷开心激情综合五月天| 日本最新免费二区三区| 国产一区二区三区美女| 亚洲熟伦熟女新五十路熟妇|